§ 27-182. Electrical.
(a)
All electric wiring shall be a minimum of 18 gauge UL-approved underground feed multi-strand for lengths of less than 500 feet, and a minimum of 14 gauge UL-approved underground feed wire for lengths over 500 feet.
(b)
All electrical connections underground shall be made by an approved waterproof connection.
(c)
All 12-volt and 24-volt wiring shall be done by the lawn sprinkler contractor.
(d)
All controllers within an internal transformer requiring hard wiring directly into circuit wiring shall have the wire installed by a licensed electrician and shall have a disconnect switch installed by the controller.
(e)
All underground electric or hydraulic control valves shall be installed in a valve box.
(f)
All exposed irrigation circuit wires above grade, before entering a structure, shall be encased in a PVC or galvanized protective conduit.
(Ord. No. 2867, § 1, 12-11-1995)