§ 27-182. Electrical.  


Latest version.
  • (a)

    All electric wiring shall be a minimum of 18 gauge UL-approved underground feed multi-strand for lengths of less than 500 feet, and a minimum of 14 gauge UL-approved underground feed wire for lengths over 500 feet.

    (b)

    All electrical connections underground shall be made by an approved waterproof connection.

    (c)

    All 12-volt and 24-volt wiring shall be done by the lawn sprinkler contractor.

    (d)

    All controllers within an internal transformer requiring hard wiring directly into circuit wiring shall have the wire installed by a licensed electrician and shall have a disconnect switch installed by the controller.

    (e)

    All underground electric or hydraulic control valves shall be installed in a valve box.

    (f)

    All exposed irrigation circuit wires above grade, before entering a structure, shall be encased in a PVC or galvanized protective conduit.

(Ord. No. 2867, § 1, 12-11-1995)